Ge GTDL740EDWW Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Secadores Ge GTDL740EDWW. GE GTDL740EDWW User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 4
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
geappliances.com or call GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
Dimensions and Installation Information (in inches)
GTDL740ED
GE
®
7.8 cu. ft. capacity long-venting electric dryer
Specification Revised 3/14
370171
Exhaust Options:
3-way via rear, right and bottom.
NEMA Receptacle codes:
3-prong dryer cord/30A/4' long (cat #WX9X2) is for
NEMA10-30R receptacle
4-prong dryer cord/30A/4' long (cat #WX9X18) is for
NEMA14-30R receptacle
Circuit Requirements:
An individual, properly-grounded branch circuit, protected
by a 30-amp circuit breaker or a time-delay fuse, is
required.
Electric Dryer Rating:
240V, 5000W, 25A, 60Hz
208V, 4784W, 23A, 60Hz
Note: Dryer wall outlet must be located within 36" of
service cord entry and accessible when dryer is mounted
in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
Special Installation Requirements
Alcove or Closet Installation:
If your dryer is approved for installation in an alcove or closet, it will be stated on a label on the dryer back.
• The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0" either side
3" front and rear
• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq. in. of
open area equally distributed. If this closet contains both a washer and a dryer, doors must contain
a minimum of 120 sq. in. of open area equally distributed.
• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
Bathroom or Bedroom Installation:
• The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence of local codes, with the National
Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
Minimum Clearances other than Alcove or Closet Installation:
Minimum clearances to combustible surfaces
0" both sides
3" rear
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - GTDL740ED

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Página 2

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Página 3

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Página 4

For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at geappliances.com or call GE Answer Center® service, 800.6

Comentários a estes Manuais

Sem comentários