Ge JGP630 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Impressoras Ge JGP630. GE JGP630 Manuel d'utilisation Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1
31-10612-2 (11-06 JR)
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com
In Canada, call 1.800.361.3400 or Visit our Website at: www.geappliances.ca
Installation
36 Sealed Gas Cooktop
Instructions
BEFORE YOU BEGIN
Read these instructions completely
and carefully.
IMPORTANT
Save these
instructions for local inspector’s use.
IMPORTANT
Observe all
governing codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these
instructions for future reference.
Product failure due to improper installation
is not covered under the Warranty.
WARNING This appliance must
be properly grounded.
IMPORTANT Leak testing of the
appliance shall be conducted according to
the manufacturer’s instructions.
Proper installation is the responsibility
of the installer and product failure due to
improper installation is NOT covered under
warranty.
IN THE COMMONWEALTH OF
MASSACHUSETTS:
This product must be installed by a
licensed plumber or gas fitter.
When using ball-type gas shut-off valves,
they shall be the T-handle type.
A flexible gas connector, when used, must
not exceed 3 feet.
JGP628, JGP630, JGP963, JGP970,
JGP975, ZGU36
FOR YOUR SAFETY:
WARNING
If the information
in this manual is not followed exactly, a fire,
explosion or gas leak may result causing
property damage, personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance!
WHAT TO DO IF YOU
SMELL GAS:
Do not try to light any appliance. Do not
touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
This cooktop has been design certified
by CSA International. You’ll find safety
precautions in your Owner’s Manual.
Read them carefully.
Installation of this cooktop must conform
with local codes or, in the absence of local
codes with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54–Latest edition.
Be sure your cooktop is installed properly
by a qualified installer or service technician.
To eliminate reaching over surface burners,
cabinet storage above burner should be
avoided.
Do not install the unit near an outside door
or where a draft may affect its use.
WARNING Disconnect all
electrical power at the main circuit breaker
or fuse box before installing.
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - Instructions

131-10612-2 (11-06 JR)Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.comIn Canada, call 1.800.361.3400 or Visit our Websi

Página 2 - IMPORTANT SAFETY INSTRUCTIONS

10Installation InstructionsCOOKTOP BURNERS ASSEMBLING THE COOKTOPBURNERSThe electrode of the spark igniter is exposed.Be careful not to push any cookt

Página 3 - PRE-INSTALLATION CHECKLIST

11Installation InstructionsBURNER GRATESThe three cooktop grates are designed forspecific positions. For maximum stability,these grates should only be

Página 4 - PREPARING THE OPENING

12Installation InstructionsOPERATION CHECKLISTMake sure all controls are left in the OFFposition. Check to be sure the cooktop is in the UNLOCKED posi

Página 5 - INSTALLING THE COOKTOP UNIT

13Installation InstructionsMAKING THE LP CONVERSIONSAFETY INFORMATION YOUSHOULD KNOW The pressure regulator and burner orificesare set for natural gas

Página 6 - INSTALLATION—GAS CONNECTIONS

14Installation InstructionsMAKING THE LP CONVERSION (CONT.)CHANGE COOKTOP BURNERORIFICESRemove the topgrates, burner caps,and burner heads.Remove the

Página 7

15Installation InstructionsUnits with 4 burnersUnits with 5 burnersInstall the LP/Propane orifices in theirprecise locations as noted in theillustrati

Página 8 - WARNING — Disconnect all

16Installation InstructionsADJUST BURNER FLAMESTurn all burners full on and check theflames. They should be blue in color withsome yellow tipping at t

Página 9

131-10612-2 (11-06 JR)Questions? Appelez le Centre de réponse 1.800.361.3400 ou visitez notre siteWeb à l’adresse : www.electromenagersge.caInstruc

Página 10 - COOKTOP BURNERS

2Instructions d’installationINSTRUCTIONS IMPORTANTES DE SÉCURITÉLa conception de votre table de cuisson a étéapprouvé par l’ACNOR International. Voust

Página 11

3Instructions d’InstallationLISTE DE VÉRIFICATION AVANT INSTALLATIONPour préparer l’ouverture de la surfacede cuisson, vous devez vous assurerque l’in

Página 12 - OPERATION CHECKLIST

2Installation InstructionsIMPORTANT SAFETY INSTRUCTIONSELECTRICAL REQUIREMENTSThis appliance must be supplied with theproper voltage and frequency and

Página 13 - MAKING THE LP CONVERSION

4Instructions d’InstallationPRÉPARATION DE L’OUVERTUREVOUS DEVEZ RESPECTER LESDÉGAGEMENTS MINIMAUXSUIVANT 13 3/4 MIN.DIMENSIONS DU DÉCOUPAGEDE LA TABL

Página 14

5Instructions d’InstallationINSTALLATION DE LA TABLE DE CUISSONPLACEZ LA PRISED’ALIMENTATIONÉLECTRIQUE ET LE ROBINETD’ALIMENTATION DE GAZ AU-DESSOUS D

Página 15

6Instructions d’installationINSTALLATION—BRANCHEMENT DU GAZFOURNISSEZ UN BONAPPROVISIONNEMENT EN GAZCette table de cuisson est conçue pourfonctionner

Página 16

7Instructions d’installationINSTALLATION SUR UN FOURENCASTRÉConsultez l’installation du four encastré poury trouver les instructions d’installation.6V

Página 17 - Table de cuisson scellée

8Instructions d’installationRALLONGESÀ cause du danger qu’elles font courir dans certaines conditions, nous vousrecommandons instamment de nes pasutil

Página 18 - Instructions d’installation

9Instructions d’installationSITUATION D’UTILISATION OÙ LECORDON D’ALIMENTATION D’UNAPPAREIL ÉLECTROMÉNAGEREST INFRÉQUEMMENTDÉBRANCHÉPour un circuit él

Página 19 - Instructions d’Installation

10Instructions d’installationBRÛLEURS DE LA TABLE DE CUISSONASSEMBLEZ LES BRÛLEURSDE LA TABLE DE CUISSONL’électrode de l’allumeur est exposée. Faitesa

Página 20 - PRÉPARATION DE L’OUVERTURE

11Instructions d’installationVÉRIFIEZ LES ALLUMEURSVous devez vérifier le fonctionnement desallumeurs électriques après vous êtresoigneusement assuré

Página 21

12Instructions d’installationLISTE DE VÉRIFICATION DE FONCTIONNEMENTAssurez-vous que tous les contrôlesrestent en position OFF (arrêt). Vérifiez que l

Página 22

13Instructions d’installationCONVERSION AU GAZ PROPANE RENSEIGNEMENTS RELATIFSÀ LA SÉCURITÉ QUE VOUSDEVEZ CONNAÎTRELes diaphragmes du régulateur de pr

Página 23

3Installation InstructionsWhen preparing cooktop opening,make sure the inside of the cabinet andthe cooktop do not interfere with eachother. (See sect

Página 24

14Instructions d’installationCONVERSION AU GAZ PROPANE (SUITE)CHANGEZ LES DIAPHRAGMESDES BRÛLEURS DE LA TABLEDE CUISSONEnlevez les grilles duhaut, les

Página 25

15Instructions d’installationAppareil avec 4 brûleursAppareil avec 5 brûleursInstallez les diaphragmes pour gaz propane à leur emplacement précis, con

Página 26

16Instructions d’installationCONVERSION AU GAZ PROPANE(SUITE)AJUSTEZ LES FLAMMES DESBRÛLEURSAllumez tous les brûleurs au maximumet vérifiez les flamme

Página 27

4Installation InstructionsPREPARING THE OPENING MAINTAIN THE FOLLOWINGMINIMUM CLEARANCEDIMENSIONS13 3/4 MIN.OVERALL COOKTOPDIMENSIONS2CUTOUT DIMENSION

Página 28

5Installation InstructionsINSTALLING THE COOKTOP UNITLOCATE ELECTRICAL OUTLETAND GAS SHUT-OFF VALVEBENEATH CABINETInstall a manual shut-off valve in t

Página 29 - CONVERSION AU GAZ PROPANE

6Installation InstructionsINSTALLATION—GAS CONNECTIONSPROVIDE ADEQUATE GAS SUPPLYThis cooktop is designed to operate onnatural gas at 4″ of water colu

Página 30

7Installation InstructionsINSTALLATION OVER BUILT-IN OVENSee built-in oven installation for completeinstallation instructions.6CHECK FOR LEAKSBefore t

Página 31

8Installation InstructionsInstallation InstructionsINSTALLATION—ELECTRICAL CONNECTIONS EXTENSION CORDSBecause of potential safety hazards undercertain

Página 32

9Installation InstructionsUSAGE SITUATIONS WHEREAPPLIANCE POWER CORD WILL BE DISCONNECTEDINFREQUENTLYFor 15 amp circuit only. Do not use an adaptoron

Comentários a estes Manuais

Sem comentários