*(,QWHUORJL[
CODE
EMERGENCY
HOME CONTROL
HOME SECURITY
Bypass
System
Status
Doors &
Windows
Motion
Sensors
Arm
Disarm
9/05/63/4 7/81/2
On OffSensorMotion TimeDoors
Lights
Chim
e
AUX
Test Weekly
POLICEFIRE
User Guide
466-1871 Rev G
January 2003
Simon
®
Security
System
Part No:
60-875
Vista de página 0
1 2 3 4 5 6 ... 35 36

Resumo do Conteúdo

Página 1 - Security

)*(,QWHUORJL[CODEEMERGENCYHOME CONTROLHOME SECURITYBypassSystemStatusDoors &WindowsMotionSensorsArmDisarm9/05/63/4 7/81/2On OffSensorMotion TimeD

Página 2 - *(,QWHUORJL[

Simon Security System5Panel announces, Motions on, Latchkey on. Arm Motion Sensors light will blink and the exit delay will begin.¾Disarming Your Sys

Página 3 - Canada Notice

Simon Security System 6The Home Control buttons are used to monitor activity within and around the home. They are not used for intrusion protection. I

Página 4 - Contents

Simon Security System7Sensor Activated LightsTurn on designated lights (with Lamp Modules) when a sensor is tripped. You can pro-gram lockout times wh

Página 5 - Contents y ii

Simon Security System 8Status BeepsNote You may receive a different number of status beeps if buttons are pressed quicklyStatus beeps are used to ind

Página 6 - Your Security

Simon Security System9Panel Indicator LightsUse the following table to understand the panel indicator lights.Numeric PagerYou may program your securit

Página 7 - Communicate

Simon Security System 10To cancel an accidental alarm before the programmed dialer delay time expires, enter your access code.Guidelines for Preventin

Página 8 - Your Control

Simon Security System11calling in a report to the central monitoring station or a pager, due to an action made by you or someone at the security syste

Página 9 - Subdisarm

Simon Security System 12Note For any keypress on the Keychain Touchpad, hold the button until the indicator light blinks.LOCK Press once to arm doo

Página 10 - Simon Security System

Simon Security System131. System must be disarmed. Open the Panel Cover by pressing the plastic latch on the top of the panel. When you open the cover

Página 11 - Time Activated Lights

Simon Security System 14Note Codes are always needed to disarm the system. Depend-ing on the panel configura-tion, codes may be needed to arm the sys

Página 12 - Communicates

FCC NoticesFCC Part 15 Information to the UserChanges or modifications not expressly approved by Interlogix Inc. can void the user’s authority to oper

Página 13 - You may receive a different

Simon Security System15Unit NumberRefers to a specific light within a house code.¾How to set time for light control:1. Open the cover of the panel.2.

Página 14 - Accidental

Simon Security System 16Option 01 - Status Beeps Add this option to enable panel beeps. Status beeps are any beeps (including chime beeps) that come f

Página 15 - Off-Site Phone

Simon Security System17Delete turns off this option and Latchkey cannot be enabled when the panel is armed.1. Open panel cover. Panel announces, Use n

Página 16 - Touchpads

Simon Security System 18Delete disables sensor activated light lockout stop time. The panel will turn on a light activated by a sensor at all times if

Página 17 - Your System

Simon Security System192. Enter Access Code using the numbered keys. Panel announces, Please select from Start Menu.3. Press Delete from the Start men

Página 18 - Access Codes

Simon Security System 20• AC Power Failures - An AC power failure is called in after loss of power. To avoid false alarms, your installer has programm

Página 19 - Delete Access Code

Simon Security System214. Press Option #. Panel announces, Option 1, press again for next option or done to select.5. Press 81. Panel announces, Optio

Página 20

Simon Security System 22System Battery FailureThis condition occurs if the emergency backup battery has failed. Status beeps will start and the SYSTEM

Página 21 - Option 03 - Latchkey Time

Simon Security System23System Access AlarmThe panel cover was opened while the system was armed. The system will call the cen-tral monitoring station

Página 22

Simon Security System 24Testing Communication Communication between your system, the central monitoring station and your pager should be tested at lea

Página 23 - Simon Security System 18

Canada NoticeThe Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain

Página 24

Simon Security System25• If sirens are not placed within hearing range of persons sleeping, in remote parts of the premises, or if they are placed beh

Página 25 - Option 81: Heating Set Point

Simon Security System 26• Escape fast! (Do not stop to pack.)• Use a different escape route if closed doors feel hot to the touch.• Crawl and hold you

Página 26 - AC Power Failure

Simon Security System27

Página 28 - Testing Sensors

Simon Security System29

Página 29 - Limitations

Simon Security System 30Access CodesMaster Access Code:______________________Access Code 1:__________________________Access Code 2:___________________

Página 30 - Emergencies

How to …Control PanelRemote HandheldTouchpadKey ChainTouchpadRemotePhoneDisarm theSystemSubdisarm theSystemArm Only - Doors& WindowsArm Only –Moti

Página 31 - Simon Security System 26

Simon Security SystemContents y iContentsIntroduction to Your Security System 1Security System Components ...

Página 32

Simon Security SystemContents y ii Trouble Beeps 21AC Power Failure ...

Página 33 - Simon Security System 28

Simon Security System1Introduction to Your Security SystemYour security system uses wireless technology to warn your family about intrusion, car-bon m

Página 34

Simon Security System 2Outdoor Motion Sensors detect motion in a protected outdoor area. When motion is detected, the system may respond by sounding c

Página 35 - Simon Security System 30

Simon Security System3How to Use Your Control PanelThe panel interface consists of four rows of buttons. Note It may be necessary to enter an access

Página 36 - Quick Reference Table

Simon Security System 4Quick Exit Note The designated door may be opened and closed once. If you close the designated door behind you when you exit,