49-7769
FEATURES OF THE ZONELINE
Features
About Your Heat Pump (on some models)
+HDWSXPSVFDQUHGXFHRSHUDWLQJFRVWVE\H[FKDQJLQJ
heat from the outside air—even when the outside
temperature is below freezing— and releasing that heat
indoors.
7RJHWWKHEHVWHFRQRPLFEHQHILWIURP\RXUKHDWSXPS
don’t change the room thermostat setting very often.
Raising the heat setting 2–3 degrees will cause the
=RQHOLQHWRXVHLWVHOHFWULFKHDWLQJHOHPHQWVLQRUGHUWR
reach the new temperature setting quickly.
7KHUHLVDWKUHHPLQXWHPLQLPXPFRPSUHVVRUUXQWLPHDW
any setting to prevent short cycling.
7KHLQGRRUIDQPRWRUVWDUWVEHIRUHWKHFRPSUHVVRUDQG
stops after the compressor cycles off.
7KHHOHFWULFKHDWLQJHOHPHQWVXVHPXFKPRUHHOHFWULFLW\
than heat pumps and cost more to operate.
Power Disconnect
7KHSRZHUGLVFRQQHFWLVORFDWHGRQWKHIURQWRIWKH
=RQHOLQH
NOTE:7KHSRZHUGLVFRQQHFWGRHVQRWUHPRYHSRZHUIURP
WKHWHUPLQDOEORFNORFDWHGXQGHUWKHFRQWUROER[SDQHO
Ventilation Control
7KHYHQWLODWLRQFRQWUROOHYHULVORFDWHGRQWKHIURQWRIWKH
=RQHOLQHXQLW
When the lever is in the CLOSE position, only the air inside
the room is circulated and filtered.
When the lever is in the OPEN position, some outdoor air
ZLOOEHGUDZQLQWRWKHURRP7KLVZLOOUHGXFHWKHKHDWLQJRU
cooling efficiency.
To close the vent, move the slide lever to the right.
To open the vent, move the slide lever to the left.
Energy Tip: Keep the vent control in the CLOSE position.
7KHURRPDLUZLOOEHILOWHUHGDQGFLUFXODWHG
NOTE: Ventilation openings are not intended to be the
source of make-up air for building ventilation systems due to
the additional heating and cooling loads generated.
Power
'LVFRQQHFW
Close
Room Freeze Protection
7KLVIHDWXUHZLOOPRQLWRUWKHLQGRRUURRPFRQGLWLRQVDQGLQ
WKHHYHQWWKDWWKHURRPIDOOVEHORZ° the unit will cycle on
KLJKIDQZLWKWKHHOHFWULFKHDWHU7KLVRFFXUVUHJDUGOHVVRI
mode as long as power is applied to the unit.
Ventilation
Control Slide
Lever
&RQWURO%R[
Panel
WARNING
Electric Shock Hazard
%HIRUHVHUYLFLQJGLVFRQQHFWSRZHUWRWKH=RQHOLQHDW
WKHIXVHER[RUFLUFXLWEUHDNHUDQGSXOORXWHOHFWULFDO
disconnect on front of the chassis.
Failure to do so can result in personal injury and/or
death.