I-60/2008
Most commonly ordered
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
UM5 UNIMOUNT
®
400 LUMINAIRE
Low Bay, Enclosed — Surface Mount Optical Series
APPLICATIONS
For 10-25 ft. (3-8 meter) applications in factories, foundries, canneries and textile,
metal, chemical, rubber, food, cement, and other industrial applications
ORDERING NUMBER LOGIC
UM5
PRODUCT
IDENT
XXX
G
COLOR
X
25
WATTAGE
XX
E
LIGHT
SOURCE
X
0
VOLTAGE
X
A
BALLAST
TYPE
X
EA
OPTICAL
CODE
XX
AG
PHOTOMETRY
CODE
XX
11
MOUNTING
CODE
XX
B
OPTIONS
X
UM5 =
Unimount
400
Luminaire
G = Gray
W = White
17 = 175
25 = 250
32 = 320
35 = 350
40 = 400
E = Energy
Act Compli-
ant Pulse MH
(EPMH)
S = HPS
For
International
Markets only
M = MH
P = Pulse
Start
MH
Note: Lamp
is vertical
base up.
Lamp not
included.
60Hz
0 =
120/208/
240/277
MULTIVOLT
1 = 120
2 = 208
3 = 240
4 = 277
5 = 480
D = 347
F =
120X347
T = 220
50Hz
6 = 220
R = 230
Y = 240
G = 380
See Ballast
Selection
Table
A =Autoreg
D =
System 3
Bi Level
Autoreg
See
technical
info
G =
(CANADIAN)
Mag-reg
with
grounded
socket
shell
H = HPF
Reactor or
Lag
L = Super
Low Loss
Autoreg
EA = Enclosed
Acrylic
Refractor
WA = Acrylic
Refractor
with inside
of Reector
Painted White
XX = Select
Code Below
XX = Select Code Below
11 = Pendant mounting
13 = Provision for Slide-on Primary Electrical
Disconnect. Order TWOBP Box (Thru Feed
Capability Only) Separately.
(Not available with W option)
14 = Provision for Slide-on Primary Electrical
Disconnect. (Pendant and Thru Feed
Capability). Order PED Box Separately
(Not available with W option)
15 = Prewire with EZ-Loop, Cord and Plug Part
of “Power Hook”. Order Receptacle/Hook
Box Separately. (Not CSA/CUL)
31 = Prewire with EZ-Hook, 3-ft (0.9 Meters)
#16/3 Cord, and Nema Plug
33 = Prewire with EZ-Loop, 3-ft (0.9 Meters)
#16/3 Cord, and Nema Plug (Order
locking receptacle hook box separately.)
67 = Pendant, Nut and Hanger Hub Mounting.
(For use with “D” or “W”, Wet Locations
Option, only)
(See pages I-153 and I-154 for details)
MODULAR PREWIRE
41 = ACS with 3-ft (0.9 meter) cord & EZ-Hook
69 = ACS with 6-ft (1.8 meter) cord & EZ-Hook
43 = ACS with 3-ft (0.9 meter) cord & EZ-Loop
70 = ACS with 6-ft (1.8 meter) cord & EZ-Loop
PLUG-N-GO
51 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Hook
71 = Plug-N-Go with 6 ft. (1.8meter) Cord & Hook
53 = Plug-N-Go with 3 ft. (0.9 meter) Cord & Loop
72 = Plug-N-Go with 6 ft. (1.8 meter) Cord & Loop
Note: ACS = Flex 3+
Plug-N-Go = FSC Series
A = 65°C maximum
ambient*
B = Time Delay
Automatically
Switched Quartz
F = Fusing (Not available
with W option)
G = Secondary
Wiring Access.
7/8 in. dia.
knockout
(Not available with W
option)
H = Charcoal Filtering
Gasket (Not available
with wet location)
Q = Non-Time Delay
Automatically
Switched Quartz
R = Non-Switched Quartz.
T = E40 / European Socket
W = Wet Location
(For use with
Mounting Code
15 and 67 only)
Y = Solo Bilevel Port
(See page I-102)
Note: See page I-104
for Accessory Index and
Descriptions.
Note: See page I-129
for explanation of Options.
*65°C available for 250
and 400 watt Auto Reg
Ballast and WA optical
only.
1598 Listed
Suitable For Damp Locations
1598 Listed for metal
halide amps in polymeric lamp
containment barriers
Listed to Canadian
standards and codes
UV stabilized injection molded
prismatic refractor for low
brightness
Enclosed and gasketed optics
In-line EZ Connect
TM
plug-in
adapter port allows for:
hook/loop, cord & NEMA plug
plug-in modular wiring
systems
plug-in fuse kits
Symmetrical heavy-duty
die-cast aluminum ballast
housing with polyester powder
gray or white paint nish
Threaded slide-in mounting
adapter for easy mounting
55° C ambient, standard
Alzak
nish on reector
Safety chain provisions
Mogul base socket -E39
standard
Shipped as components:
Ballast, Optical
Magnapack available
for ballast
Pulse start system for metal
halide available. See Page I-131
SPECIFICATION FEATURES
With
EZ Connect
TM
EA OPTICAL - Enclosed Optical
Light Spacing Socket Photometric Optical
Photometry
Wattage Source Criteria Position Curve Code Code
175,250 EPMH 1.7 G 177155 EA AG
320(ED28)*
EPMH 1.7 G 177155 EA AG
350 EPMH 1.9 A 177013 EA AA
400 EPMH 1.9 A 177013 EA AA
400 EPMH(Coated) 1.6 A 177014 EA AA
250 HPS 1.9 F 177011 EA AF
400 HPS 1.9 F 177011 EA AF
WA OPTICAL - Enclosed Optical with White Inside Reector
Light Spacing Socket Photometric Optical
Photometry
Wattage Source Criteria Position Curve Code Code
175,250 EPMH 2.0 H 178672
WA
AH
320(ED28)*
EPMH 2.0 H 178672
WA
AH
350 EPMH 2.0 A 178674
WA
AA
400 EPMH 2.0 A 178674
WA
AA
400 EPMH(Coated) 1.4 A 451384
WA
AA
250 HPS 2.0 F 178673
WA
AF
400 HPS 2.0 F 178673
WA
AF
PHOTOMETRIC SELECTION TABLE
*320 watt, ED28 pulse start MH
Note: See page T-34 for Alternative lens material explanation
Vista de página 0
1 2

Resumo do Conteúdo

Página 1 - 400 LUMINAIRE

I-60/2008 Most commonly orderedGE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com1 - 8 8 8 - 6 9 - 4 3 - 5 3 3UM5 UNIMOUNT® 40

Página 2

2008/I-61GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com1 - 8 8 8 - 6 9 - 4 3 - 5 3 3UM5 UNIMOUNT® 400 LUMINAIRELow Bay Enc

Comentários a estes Manuais

Sem comentários