Typical Layouts
Luminaire Selection
No individual floodlight should produce more than the average design illumination level at any point on the
field. Floodlights with too narrow beam type will cause hot spots and poor uniformity. The beam type
selection, therefore, is always a function of the light level and the pole setback. This is the reason why fixtures
from different manufacturers cannot be relied on to produce the same light levels or uniformity.
Aiming Diagrams
Individual aiming diagrams are available for each recommended system. Where the setback is different on the
two sides of the field, order the diagrams for each setback and aim each side accordingly. Recommendations
for higher light levels or for TV lighting should be referred to the Application Engineering unit at the factory.
18 877-798-6702 www.GELightingSystems.com