Sports Lighting
Gymnasium Lighting
Court Layouts
Room reflectances: 50/30/20
Dotted circles indicate luminaire positions. Layouts given are suggestions only. Luminaires should be mounted
over the court, in a fairly uniform pattern, but placement is not critical. No matter what the spacing is, the
average light level will remain about the same so long as the suggested number of luminaires is used, and all
are over the court.
Light level data applies just to the court, but no
additional lighting is needed in the gym if the
area around the court does not extend further
than 5’ at each basket end and 30’ along the
side lines. Larger rooms may require additional
luminaires.
Room reflectances: 50/30/20.
(These multiple court designs are generally
for newer facilities, so ceiling reflectances are
higher.)
Room size: 140’ wide by 130’ long.
Room consists of center main court and two
cross-wise practice courts. Eliminate or add
luminaires for different size rooms.
Luminaire: Versabeam
TM
with NuVation
TM
electronic
ballast with pulse start metal halide VBU.*
36 Luminaires 22’x 22’ spacing
Main court: 59 fc; uniformity 1.2 max/min*
Practice courts: 59 fc; uniformity 1.2 max/min*
8 Luminaires 32 fc; uniformity 1.3 max/min*
14 Luminaires 55 fc; uniformity 1.4 max/min*
24 Luminaires 87 fc; uniformity 1.3 max/min*