GE PT878 Manual do Utilizador Página 229

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 297
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 228
Chapter 10. Specifications
Transport® Model PT878 Portable Liquid Flowmeter User’s Manual 213
Chapter 10.Specifications
This section contains specifications for the following:
Overall
Electrical
Transducer
Fluid Types
Pipe Size and Materials
Available Options
10.1 Overall
10.1.1 Hardware Configuration
Channel Options: Single channel
Mode Options: Transit-time
10.1.2 Size/Weight
Size without boot: 238 × 138 × 38 mm
(9.4 × 5.5 × 1.5 inches)
Weight with boot: 1.36 kg (3 lb)
10.1.3 Enclosure
Submersible, IP67
10.1.4 Flow Accuracy (Velocity, % of reading):
Clamp-on Transducers: Pipe Diameter > 150 mm (6 in.)
±1% to 2% of reading typical
Pipe Diameter 150 mm (6 in.)
±2 to 5% of reading typical
Vista de página 228
1 2 ... 224 225 226 227 228 229 230 231 232 233 234 ... 296 297

Comentários a estes Manuais

Sem comentários