GE PT878GC Manual do Utilizador Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 308
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
April 2004
3-26
Installing DMP-3 Compound with All Fixtures
1. Be sure the fixture and transducers are installed on the pipe as
described in the previous sections of this chapter.
2. Remove the fixture and transducers, but be sure to mark the
approximate area of installation.
3. Remove any loose paint or rust with a file or emery cloth, as
shown in Figure 3-29a below. If the finish is mirror-smooth,
roughen the surface.
Figure 3-29: Filing (a) and Degreasing (b) the Pipe
Surface
4. While wearing appropriate gloves, degrease the surface as
shown in Figure 3-29b above.
5. Place a piece of the DMP-3 material on top of the pipe (Figure
3-30a), and use the palm of the hand to press it onto the pipe
(see Figure 3-30b below).
Figure 3-30: Applying the DMP-3 Material
(a)
(b)
(a)
(b)